Slurry tank depth and S.I. 113 storage calculations

Under S.I. No. 113 of 2022, Irish farms must hold 16 weeks of slurry in Zone A, 18 weeks in Zone B, 20 weeks in Donegal and Leitrim, and 22 weeks in Cavan and Monaghan. Always subtract 200 mm indoor freeboard (or 300 mm outdoor) from internal tank depth.

How county storage weeks, weekly livestock slurry outputs and mandatory 200 mm freeboard set whether you pour an 8 ft, 9 ft or 10 ft deep tank.

Free, no obligation. One local builder prices it, not five.

  • 16–22 wksS.I. 113 county storage zones
  • 200 mmmandatory indoor tank freeboard
  • 2.4–2.7 mtypical internal cattle tank depth
  • 0.26–0.33 m³weekly adult cattle slurry range
Ready-mix concrete being poured into an excavated foundation beside stacked steel reinforcement bars

Worked slurry formula: stock × weekly rate × zone weeks

Size your underground tank before finalising slat length or dig depth. Multiply head count by the statutory S.I. 113 Table 2 weekly rate and your county's storage weeks, then divide by internal tank floor area and add 0.20 m indoor freeboard.

Dairy cow (note: moving toward 0.40 m³)

Weekly slurry (S.I. 113)
0.33 m³ / wk
16-wk Zone A total
5.28 m³ / cow
22-wk Zone C+ total
7.26 m³ / cow

Suckler cow

Weekly slurry (S.I. 113)
0.29 m³ / wk
16-wk Zone A total
4.64 m³ / cow
22-wk Zone C+ total
6.38 m³ / cow

Cattle over 2 years (finishers)

Weekly slurry (S.I. 113)
0.26 m³ / wk
16-wk Zone A total
4.16 m³ / head
22-wk Zone C+ total
5.72 m³ / head

Cattle 1 to 2 years (stores)

Weekly slurry (S.I. 113)
0.22 m³ / wk
16-wk Zone A total
3.52 m³ / head
22-wk Zone C+ total
4.84 m³ / head

Cattle 0 to 1 year (weanlings)

Weekly slurry (S.I. 113)
0.15 m³ / wk
16-wk Zone A total
2.40 m³ / head
22-wk Zone C+ total
3.30 m³ / head

Lowland ewe

Weekly slurry (S.I. 113)
0.03 m³ / wk
16-wk Zone A total
0.48 m³ / ewe
22-wk Zone C+ total
0.66 m³ / ewe

Work out your slatted shed cost

Four quick taps and our bay-by-bay price shows before we ask for a phone number. One local farm shed builder rings you, not five.

4 bays slatted tank and slats, TAMS 3 still to decide: €44,000 to €72,000 ex VAT.

Step 1 of 5

Which slatted build are you pricing?

Pick the closest match. One builder checks exact spans on site.

How the bay-by-bay figure is worked out

The guide multiplies going Irish per-bay slatted build ranges (excavation, shuttered reinforced tank, gang slats, external agitation point, steel frame, cladding and penning) by bay count, ex VAT. When you select 40% or 60% TAMS 3, the indicative net figure deducts grant aid up to a single €90,000 investment ceiling; splitting slurry storage under the separate 60% Nutrient Storage ceiling or building as a registered farm partnership (€160,000 ceiling) increases grant support further. Rock breaking, high water tables, rubber slat mats and extra feed passage widths are priced when the builder walks the yard.

Choosing between 2.4 m (8 ft), 2.7 m (9 ft) and 3.0 m (10 ft) tank depth

2.4 m (8 ft) internal depth (2.2 m usable after 200 mm freeboard) is the Irish standard because standard 2.4 m steel shuttering panels match it in a single pour and groundwater is easier to manage. 2.7 m (9 ft) internal depth adds 13.6% usable storage for very little extra excavation on dry ground, making it popular in 20-week and 22-week Zone C counties or dairy expansion builds. 3.0 m (10 ft) deep tanks demand heavier vertical steel reinforcement, thicker walls and stronger dewatering controls; only dig past 2.7 m after checking trial holes for rock and water tables.

  • Example 4-bay tank (19.2 m × 4.12 m clear inside × 2.4 m deep): Gross volume 189.8 m³; usable volume at 2.2 m depth is 174.0 m³, covering 33 suckler cows in Zone B (18 wks) or 41 finishing bullocks in Zone A (16 wks).
  • Allow for dirty yard runoff and washings. Any open concrete apron or unroofed scraper passage draining into the tank must also store winter rainfall under S.I. 113.

Common slatted shed questions

Why must I deduct 200 mm freeboard from tank depth?

DAFM S.123 mandates 200 mm air space below indoor slats (300 mm on uncovered outdoor tanks) so slurry never backs up onto slats during winter or spills over during agitation.

What happens if we hit rock at 1.8 m depth?

You have two choices: rock-break down to 2.4 m (paying hourly rock-breaker rates) or widen the tank using 16 ft 6 in slats or add an extra bay length so required cubic metres are achieved shallower.

Is dairy cow slurry storage increasing from 0.33 m³ per week?

Yes, updated Nitrates Action Programme guidance moves higher-yielding dairy cows toward 0.40 m³ per week, so building 15% to 20% spare tank depth now protects compliance for the next decade.

Does straw bedding reduce slurry tank volume needed?

Partially bedded suckler housing where cows spend time on solid straw lie-backs can split excreta between farmyard manure and liquid slurry according to Nitrates rules; confirm exact deductions with your agricultural advisor.

All slatted shed pages and technical guides

Double-sided steel cattle shed with a wide central concrete feed passage and a tractor at the far gable

See your bay-by-bay cost before a builder rings

Pick the slatted shed layout, bay count, TAMS 3 rate and county. When you want a site quote, your outline goes to a single farm shed builder in your county.